0.6/1kV Low Smoke Halogen Free Cable Shanghai manufacturer CU/XLPE/LSZH ROHS CE Certified
. Application for Fire Resistive Power Cable, Fire Rated Power Cable
| Conductor | : | Plain Annealed, Stranded Circular Non – Compacted or Circular Compacted or Shaped Copper |
|---|---|---|
| Fire Barrier | : | Mica Tape |
| Insulation | : | XLPE (For FR-200) or LSOH (For FR-300) |
| Sheath | : |
LSOH |
| Conductor | : | Plain Annealed, Stranded Circular Non – Compacted or Circular Compacted or Shaped Copper |
|---|---|---|
| Fire Barrier | : | Mica Tape |
| Insulation | : | XLPE (For FR-200) or LSOH (For FR-300) |
| Sheath | : | LSOH |
| Insulation Colour | : |
2C – Brown & Blue 3C – Brown, Black & Grey 4C – Brown, Black, Grey & Blue 2C+E – Brown, Blue + Green/Yellow 3C+E – Brown, Black, Grey + Green/Yellow 4C+E – Brown, Black, Grey, Blue + Green/Yellow 5C & above – White Cores Printed With Number |
Note:
1. The models also contain fire-resistant type of low voltage power cable.
2. When signing the contract, the fire resistant type must be specified. For example, if type A is preferred, please add "A" to the end of "ZR", forming "ZRA", and A is usually used in places where the fire resistant property is highly required. B and C follow the same rule. In addition, if there is no letter after "ZR", the cable will be produced following "ZRC".
![]()
|
|
| الـ MOQ: | 300m |
| السعر: | 0.38-25.6 |
| العبوة القياسية: | طبل خشبي أو حالة |
| فترة التسليم: | حسب الجدول الزمني |
| طريقة الدفع: | L / C ، T / T |
| قدرة التوريد: | 50KM / شهر |
0.6/1kV Low Smoke Halogen Free Cable Shanghai manufacturer CU/XLPE/LSZH ROHS CE Certified
. Application for Fire Resistive Power Cable, Fire Rated Power Cable
| Conductor | : | Plain Annealed, Stranded Circular Non – Compacted or Circular Compacted or Shaped Copper |
|---|---|---|
| Fire Barrier | : | Mica Tape |
| Insulation | : | XLPE (For FR-200) or LSOH (For FR-300) |
| Sheath | : |
LSOH |
| Conductor | : | Plain Annealed, Stranded Circular Non – Compacted or Circular Compacted or Shaped Copper |
|---|---|---|
| Fire Barrier | : | Mica Tape |
| Insulation | : | XLPE (For FR-200) or LSOH (For FR-300) |
| Sheath | : | LSOH |
| Insulation Colour | : |
2C – Brown & Blue 3C – Brown, Black & Grey 4C – Brown, Black, Grey & Blue 2C+E – Brown, Blue + Green/Yellow 3C+E – Brown, Black, Grey + Green/Yellow 4C+E – Brown, Black, Grey, Blue + Green/Yellow 5C & above – White Cores Printed With Number |
Note:
1. The models also contain fire-resistant type of low voltage power cable.
2. When signing the contract, the fire resistant type must be specified. For example, if type A is preferred, please add "A" to the end of "ZR", forming "ZRA", and A is usually used in places where the fire resistant property is highly required. B and C follow the same rule. In addition, if there is no letter after "ZR", the cable will be produced following "ZRC".
![]()