logo
Qingdao Yilan Cable Co., Ltd.
المنزل > المنتجات > انخفاض دخان صفر كابل الهالوجين >
Black Low Smoke Zero Halogen Cable LSZH Cables for Smoke Emission / Toxic Fumes
  • Black Low Smoke Zero Halogen Cable LSZH Cables for Smoke Emission / Toxic Fumes
  • Black Low Smoke Zero Halogen Cable LSZH Cables for Smoke Emission / Toxic Fumes
  • Black Low Smoke Zero Halogen Cable LSZH Cables for Smoke Emission / Toxic Fumes
  • Black Low Smoke Zero Halogen Cable LSZH Cables for Smoke Emission / Toxic Fumes
  • Black Low Smoke Zero Halogen Cable LSZH Cables for Smoke Emission / Toxic Fumes

Black Low Smoke Zero Halogen Cable LSZH Cables for Smoke Emission / Toxic Fumes

مكان المنشأ الصين
اسم العلامة التجارية QINGDAO YICABLE CABLE
إصدار الشهادات KEMA,ISO,CE,IEC,PICC
تفاصيل المنتج
قائد نوع:
الذين تقطعت بهم السبل Class2
تصنيف درجة الحرارة:
-20 درجة مئوية إلى + 90 درجة مئوية
الحد الأدنى نصف قطرها الانحناء:
12 × القطر الكلي
غمد اللون:
أسود
اساسي:
iec
تطبيقات:
انبعاثات الدخان والأبخرة السامة
إبراز: 

lszh power cable

,

xlpe lszh cable

Payment & Shipping Terms
الحد الأدنى لكمية
1000meters
الأسعار
US$1.0~120per meter
تفاصيل التغليف
طبل الحديد والخشب
وقت التسليم
اعتمادا على كمية الطلب
شروط الدفع
L / C ، T / T
القدرة على العرض
30Kilometer / شهر
وصف المنتج

LSZH Cables for Use in Applications Smoke Emission and Toxic Fumes

 

APPLICATION

 

 These power cables are used for electricity supply in low voltage installation system. They are well adapted to underground use in industrial applications with an additional mechanical protection. These cables can be fixed on cable trays, within conduits or fixed to walls.

 

CONSTRUCTION

 

Conductor Up to 35mm2: Class 1 solid copper conductor to 16mm2 Above 35mm2: Class 2 stranded copper conductor

Insulation XLPE (Cross-Linked Polyethylene) Type 2XI1 according to VDE 0276 Part 604 Sheath LSZH (Low Smoke Zero Halogen) Type HM4 according to VDE 0276 Part 604

 

Main features
1. Ordinary flame retardant cable
For Class A and Class B fire tests, the fire time is 40 minutes, and for Class C and Class D fire tests, the fire time is 20 minutes, and the charring height does not exceed 2.5 m.
2. Low-halogen low-smoke flame retardant cable
Halogen acid gas emission <100 mg/g, smoke density (transmittance) > 30%, from the group burning test, it meets the requirements of Class C flame retardancy.
3. Low smoke zerohalogen (LSZH) flame retardant cable:
Halogen acid gas all-emission 0 mg/g, pH value ≥ 4.3, conductivity ≤ 10 us/mm, toxicity index ≤ 5. From the group burning test, it at least meets the requirements of Class C flame retardancy, smoke density (transmittance) ≥
60%.
4. Oxygen barrier cable (highly-flame retardant cable)
From the group burning test, it meets and exceeds the requirements of Class A flame retardancy, and the smoke density (transmittance) is equal to or close to national standard GB/T17651-2008 and international standard IEC61034 low smoke standard.
It is especially suitable for 6 KV-35 KV medium-voltage cable frame retardancy, has not only flame retardancy up to Class A, but also has certain refractory characteristics (i.e. can still keep 2.4 Uo insulation standard after burning for 20 min).
Notes: Users can select category and class of flame retardant cable according to laying places.

 

Black Low Smoke Zero Halogen Cable LSZH Cables for Smoke Emission / Toxic Fumes 0

المنتجات الموصى بها

اتصل بنا في أي وقت

+86 19026815676
شرق شارع بينغآن ، مدينة جياوكسي ، مدينة جياوتشو ، مقاطعة شاندونغ
أرسل استفسارك مباشرة إلينا